thermal load in a sentence
Examples
- A conventional X-ray tube for mammography consumes 4.5-6 kilowatts, and calls for a Coolidge tube with a rotational anode in order to spread the thermal load from a single spot to the edge area of a spinning anode disc.
- One type of xenon arc lamp ( originally called the " Cermax " ), which is now known generically as the " ceramic body xenon lamp ", uses sapphire crystal output windows that tolerate higher thermal loads and thus higher output powers when compared with conventional Xe lamps with pure silica window.
- Combining these two orders of magnitude gains, the thermal load of 6.5 kilowatts reduces to a load below 100 watts, which can easily be managed in a stationary anode with a sharp focal spot well below 100 �m without active cooling, or at 40-50 �m with active air cooling to the tube anode.
- Fusible plugs are common in aircraft wheels, typically in larger or high-performance aircraft . The very large thermal loads imposed by abnormal landing and braking conditions ( and RTO notably ) can cause already high pressure in the tyres to rise to the point that the tyre might burst, so fusible plugs are used as a relief mechanism.
- The end-point of a given overclock is determined by parameters such as available CPU multipliers, bus dividers, voltages; the user's ability to manage thermal loads, cooling techniques; and several other factors of the individual devices themselves ( which the user cannot control, just " luck of the draw " if a part is a " good clocker " or not ) such as semiconductor clock and thermal tolerances, interaction with other components and the rest of the system.
- In addition to the overall scientific coordinating responsibilities, he developed many of the approaches and algorithms related to the mission : his innovation, insight and mathematical rigour impacted the optical and focal plane design, the instrument calibration, the scanning law, the attitude determination ( and the associated ` dynamical smoothing'), the double star analysis ( as observed via a signal modulated by a grid ), the effects of chromaticity and thermal load fluctuations, the optimum combination of the NDAC and FAST catalogue solutions, and the link to an extragalactic reference frame.
- The transmission target emission angle whose total X-ray fluence, mostly in line-emission, could be 250 times that of the Coolidge tube with kVp reaching 100kV . Most importantly, by making use of a greatly enhanced X-ray generating efficiency, the thermal load of a medical imaging unit such as mammography operating at 100kV without a spectrum shift, can be reduced from 6 kW to under 100 Watts, for example, thus providing the X-ray tube to deliver a sharper focal spot with much improved line-pair formation in the imager.